Vents Micra 110 V1 ERV

Decentralized supply and exhaust unit with heat recovery. Air flow: up to 100 m³/h
  • Maximum airflow: 100 m3/h
  • Sound pressure level LpA at 3 m: 31 dB(A)
  • Sound pressure level LpA at 1 m: 40 dB(A)
  • Heat recovery efficiency: 85 %
  • Heat exchanger type: Counter flow
  • Extract filter: G4
  • Supply filter: G4 опция: F7, G4 option: F7
  • Sound insulation
  • Motor type: EC
  • Enthalpy heat exchanger
  • Control: Built-in control panel
  • Casing material: Galvanized steel
  • Humidity sensor: Built-in
  • Temperature sensor: Built-in
Unit of measurement Micra 110 V1 ERV
Connected air duct size mm 100
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 10 15 31
Unit current A 0.26
Maximum airflow m3/h 30 60 100
Sound pressure level LpA at 3 m dB(A) 10 21 31
Sound pressure level LpA at 1 m dB(A) 20 30 40
Heat recovery efficiency % 85 80 72
Heat exchanger type - Counter flow
Heat exchanger material - Enthalpy
Weight kg 23
Extract filter - G4
Supply filter - G4 опция: F7, G4 option: F7
Transported air temperature (max) °С 40
Transported air temperature (min) °С -15
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP20
Ingress protection rating of the drive - IP44
Vents Micra 110 V1 ERV 41 100 2018
Trademark Vents
Model Micra 110 V1 ERV
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
76.6 A+ 39.5 A 15.6 E
Type of ventilation unit Bidirectional
Type of drive installed 3-speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery at reference point (%) 80
Maximum flow rate (m3/h) 100
Electric power input (W) 30.6
Reference flow rate (m3/s) 0.017
Specific power input (SPI) (W/(m3/h)) 0.252
Control typology Local demand control
Maximum internal leakage rates (%) 1.7
Maximum external leakage rates (%) 4.7
Mixing rate (%) 1
Airflow sensitivity at +20 Pa and -20 Pa (%) 0
Declared typology RVU BVU
Sound power level (dB(A)) 41
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
764 227 182
The annual heating saved (AHS) (kWh/a) Cold Average Warm
8695 4445 2010
Datasheet
"VENTS Micra 110" product description 03-2023
2.27 Mb
Manual
"VENTS Micra 110" user's manual 12-2022 (V250EN-02)
4.87 Mb
Manual
"MK Micra 110" installation instruction 10-2022 (V250-2EN-01)
465 Kb
Manual
"Electric heater NE Micra" user's manual 11-2022 (V73-8EN-03)
1.88 Mb
Manual
"MK1 Micra 110" installation instruction 06-2022 (V250-1EN-01)
199 Kb
Manual
"VENTS Micra 110" user's manual 01-2024 (V250EN-02)
5.81 Mb
Image
Micra 110 V1 ERV - image 1
167 Kb
Vents Micra 110 V1 ERV - Dimensions
Other accessories
Name Photo Description
Vents SF 176x160x22 G4 SF 176x160x22 G4 Panel filter G4
Vents SF 203x150x22 G4 SF 203x150x22 G4 Panel filter G4
Vents SF 203x150x22 F7 SF 203x150x22 F7 F7 panel filter
Vents MK Micra 110 MK Micra 110 Mounting kit: Two plastic air ducts; Outdoor box; Cardboard template
Vents MK Micra 110 chrome MK Micra 110 chrome Mounting kit: Two plastic air ducts; Outdoor box; Cardboard template
Vents MK Micra 110 white MK Micra 110 white Mounting kit: Two plastic air ducts; Outdoor box; Cardboard template
Vents MK1 Micra 110 MK1 Micra 110 Mounting kit for corner mounting of the grille in the window opening
Vents MK1 Micra 110 chrome MK1 Micra 110 chrome Mounting kit for corner mounting of the grille in the window opening
Vents MK1 Micra 110 white MK1 Micra 110 white Mounting kit for corner mounting of the grille in the window opening
Vents NB Micra 110 NB Micra 110 Outdoor box
Vents NB Micra 110 chrome NB Micra 110 chrome Outdoor box
Vents NB Micra 110 white NB Micra 110 white Outdoor box
Vents NE Micra 100 NE Micra 100 Heater to prevent condensate freezing in the drain pipe and the outdoor box
Name Photo Description
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents CO2-3 CO2-3 CO2 sensor
Vents HR-S HR-S Electro-mechanical humidistats
Name Photo Description
Vents FlexiVent 0275 FlexiVent 0275 For connection of the air ducts to the connectors and air distribution boxes